Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SNC101
Output Voltage:
0~100V
Output Current:
0~6A
Display Resolution:
0.1V/0.001A
Display Accuracy:
±1%RD±0.5%FS
Capacitance Range:
1000uF~100mF
Gear Selection:
Automatic Selection
Minimum Resolution:
1000uF
Volumetric Accuracy:
±20%
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 days
Payment Terms:
T/T
Supply Ability:
10 Sets Per Month
High Light:

Fig 101 Operation Test Apparatus

,

Battery Charger Operation Test Apparatus

,

IEC 60335-2-29 Operation Test Apparatus

Product Description

 

IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test

 

 

Product information:

 

Charger Normal Working Test Equipment is a professional testing equipment that simulates the normal working conditions of a battery charger under load. Designed according to GB/T4706.18-2014/IEC60335-2-29:2010 relevant standards. This equipment mainly consists of DC power supply, capacitive load, resistor and control system. It adopts 7-inch industrial control screen for operation and display, and is controlled by PLC. It has the characteristics of easy operation, automatic parameter setting, one-click start, and high stability.

 

Test schematic diagram:

 

IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test 0

Technical Parameters:

 

Precharged DC power supply
Output voltage range 0~100V
Output current 0~6A
Voltage/current display resolution 0.1V/0.001A
Display accuracy ±1%RD±0.5%FS
Capacitance
Capacitance range 1000uF~100mF
Minimum resolution 1000uF
Gear selection Automatic selection
Volumetric accuracy ±20%
Resistance
Resistance range: 0.1~100Ω
Rated current 20A
Minimum resolution 0.1Ω
Gear selection Automatic selection
Volumetric accuracy ±20%
Control system
Charger output voltage range 12~72V
Maximum output current 20A
Precharge voltage range 0 to 72V, can be set.
Voltage detection range 0~100V
Display resolution 0.01V
Display accuracy ±1%±0.5%FS
Current detection range 0~20A
Display resolution 0.001A
Display accuracy ±1%±0.5%FS
Control mode PLC
Display mode 7 inch display
Test station 1 station
Working environment

Temperature: 5℃ ~ 40℃, indoor

Humidity: less than 75% RH, no frost

Equipment size 450X550X235mm
 

IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test 1

 

IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test 2

products
PRODUCTS DETAILS
IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SNC101
Output Voltage:
0~100V
Output Current:
0~6A
Display Resolution:
0.1V/0.001A
Display Accuracy:
±1%RD±0.5%FS
Capacitance Range:
1000uF~100mF
Gear Selection:
Automatic Selection
Minimum Resolution:
1000uF
Volumetric Accuracy:
±20%
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 days
Payment Terms:
T/T
Supply Ability:
10 Sets Per Month
High Light

Fig 101 Operation Test Apparatus

,

Battery Charger Operation Test Apparatus

,

IEC 60335-2-29 Operation Test Apparatus

Product Description

 

IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test

 

 

Product information:

 

Charger Normal Working Test Equipment is a professional testing equipment that simulates the normal working conditions of a battery charger under load. Designed according to GB/T4706.18-2014/IEC60335-2-29:2010 relevant standards. This equipment mainly consists of DC power supply, capacitive load, resistor and control system. It adopts 7-inch industrial control screen for operation and display, and is controlled by PLC. It has the characteristics of easy operation, automatic parameter setting, one-click start, and high stability.

 

Test schematic diagram:

 

IEC 60335-2-29 Fig 101 Charger Normal Operation Test Apparatus For Battery Charger Test 0

Technical Parameters:

 

Precharged DC power supply
Output voltage range 0~100V
Output current 0~6A
Voltage/current display resolution 0.1V/0.001A
Display accuracy ±1%RD±0.5%FS
Capacitance
Capacitance range 1000uF~100mF
Minimum resolution 1000uF
Gear selection Automatic selection
Volumetric accuracy ±20%
Resistance
Resistance range: 0.1~100Ω
Rated current 20A
Minimum resolution 0.1Ω
Gear selection Automatic selection
Volumetric accuracy ±20%
Control system
Charger output voltage range 12~72V
Maximum output current 20A
Precharge voltage range 0 to 72V, can be set.
Voltage detection range 0~100V
Display resolution 0.01V
Display accuracy ±1%±0.5%FS
Current detection range 0~20A
Display resolution 0.001A
Display accuracy ±1%±0.5%FS
Control mode PLC
Display mode 7 inch display
Test station 1 station
Working environment

Temperature: 5℃ ~ 40℃, indoor

Humidity: less than 75% RH, no frost

Equipment size 450X550X235mm
 