Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus

IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus

MOQ: 1
Price: Customized
Standard Packaging: Plywood
Delivery Period: 1 Month
Payment Method: T/T
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN1108
Applied Standard:
IEC60335-1
Applied Clause:
Clause 22.16
Input Power:
220V/50Hz
Test Speed:
30 Cycles / Min
Test Cycles:
0~9999 Times
Drive Mode:
Pneumatic
Drawable Angle:
30~70°
Drawable Stroke:
Maximum 1000mm
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood
Delivery Time:
1 Month
Payment Terms:
T/T
Supply Ability:
20 Sets Per Month
High Light:

Flexible Cord Withdrawn Testing Apparatus

,

Automatic Cord Reels Withdrawn Testing Apparatus

,

IEC 60335-1 Withdrawn Testing Apparatus

Product Description

 

IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus

 

Standards for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

This device meets the standards of IEC 60335-1 Clause 22.16

 

Application for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

It is used to check the automatic cord reels shall be constructed so that they do not cause

– undue abrasion or damage to the sheath of the flexible cord;

– breakage of conductor strands;

– undue wear of contacts.

 

Technical Characteristics for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

Input Power 220V/50Hz
Gas Source Pressure 0.6MPa
Test Speed 30 cycles / min (or at the maximum rate allowed by the construction of the cord reel if this is less)
Test Cycles 0~9999 times, the test device will stop working automatically when the preset test cycles are finished
Drive Mode Pneumatic
Withdrawable Angle 30~70°, can be preset
Fixture Quick clamping fixtures, easy for clamping the test sample
Withdrawable Stroke Maximum 1000mm, can be adjusted
 

Test procedures (extracted from IEC 60335-1: 2016 clause 22.16):

 

Two-thirds of the length of the cord is inreeled. If the withdrawable length of the cord is less than 225cm, the cord is unreeled so that a length of 75cm remains on the reel. An additional length of 75cm of the cord then unreeled and pulled in a director so that the greatest abrasion occurs to the sheath, taking into account the normal position of use of the appliance. Where the cord leaves the appliance, the angle between the axis of the cord during the test and the axis of the cord when it is unreeled without substantial resistance is approximately 60°. The cord is allowed to be recoiled by the reel.

 

If the cord does not recoil at the angle of 60°, this angle is adjustaed to the maximum that will allow recoil.

 

The test is carried out 6000 times at a rate of approximately 30 times per minute or at the maximum rate allowed by the construction of the cord reel if this is less.

 

Test sample for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

Automatic cord reels of household appliances and similar electrical appliances.

Feature: The device adopts a multi-functional fixture, large work surface, can test cord reels up to 300cm, test speed (5-30 times / min) is adjustable, and it is suitable for most test electrical products.

 

How to install the test sample on the proper position?

 

The nut of the sample mounting platform is placed in the groove and can be moved. Therefore, the fixing bracket can be installed at any position to accommodate various samples. If the sample reel has the control switch, should make the control switch in the open state. Shown as following:

 

IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus 0

products
PRODUCTS DETAILS
IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus
MOQ: 1
Price: Customized
Standard Packaging: Plywood
Delivery Period: 1 Month
Payment Method: T/T
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN1108
Applied Standard:
IEC60335-1
Applied Clause:
Clause 22.16
Input Power:
220V/50Hz
Test Speed:
30 Cycles / Min
Test Cycles:
0~9999 Times
Drive Mode:
Pneumatic
Drawable Angle:
30~70°
Drawable Stroke:
Maximum 1000mm
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood
Delivery Time:
1 Month
Payment Terms:
T/T
Supply Ability:
20 Sets Per Month
High Light

Flexible Cord Withdrawn Testing Apparatus

,

Automatic Cord Reels Withdrawn Testing Apparatus

,

IEC 60335-1 Withdrawn Testing Apparatus

Product Description

 

IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus

 

Standards for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

This device meets the standards of IEC 60335-1 Clause 22.16

 

Application for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

It is used to check the automatic cord reels shall be constructed so that they do not cause

– undue abrasion or damage to the sheath of the flexible cord;

– breakage of conductor strands;

– undue wear of contacts.

 

Technical Characteristics for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

Input Power 220V/50Hz
Gas Source Pressure 0.6MPa
Test Speed 30 cycles / min (or at the maximum rate allowed by the construction of the cord reel if this is less)
Test Cycles 0~9999 times, the test device will stop working automatically when the preset test cycles are finished
Drive Mode Pneumatic
Withdrawable Angle 30~70°, can be preset
Fixture Quick clamping fixtures, easy for clamping the test sample
Withdrawable Stroke Maximum 1000mm, can be adjusted
 

Test procedures (extracted from IEC 60335-1: 2016 clause 22.16):

 

Two-thirds of the length of the cord is inreeled. If the withdrawable length of the cord is less than 225cm, the cord is unreeled so that a length of 75cm remains on the reel. An additional length of 75cm of the cord then unreeled and pulled in a director so that the greatest abrasion occurs to the sheath, taking into account the normal position of use of the appliance. Where the cord leaves the appliance, the angle between the axis of the cord during the test and the axis of the cord when it is unreeled without substantial resistance is approximately 60°. The cord is allowed to be recoiled by the reel.

 

If the cord does not recoil at the angle of 60°, this angle is adjustaed to the maximum that will allow recoil.

 

The test is carried out 6000 times at a rate of approximately 30 times per minute or at the maximum rate allowed by the construction of the cord reel if this is less.

 

Test sample for Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus:

 

Automatic cord reels of household appliances and similar electrical appliances.

Feature: The device adopts a multi-functional fixture, large work surface, can test cord reels up to 300cm, test speed (5-30 times / min) is adjustable, and it is suitable for most test electrical products.

 

How to install the test sample on the proper position?

 

The nut of the sample mounting platform is placed in the groove and can be moved. Therefore, the fixing bracket can be installed at any position to accommodate various samples. If the sample reel has the control switch, should make the control switch in the open state. Shown as following:

 

IEC 60335-1 Automatic Cord Reels Flexible Cord Withdrawn Testing Apparatus 0